Call Us
Email
Leave Us a Message
Whether you require a quote, have questions or need assistance, our team is ready to provide expert guidance.
Contact Form

CAAI Cable

Aluminum conductors with aluminum alloy support conductors make up CAAI. The support conductor can be either bare (designated “ND”) or insulated (designated “NA”).

With voltages up to 1000 V, this cable is typically utilized for overhead secondary distribution networks in urban and rural areas. They provide greater spans, lower mounting, little support, and easier installation, especially in densely populated regions or areas where trees are present. Additionally, it provides the greatest level of employee safety and outage protection. High dependability over many years of use is ensured by resistance to abrasion, flexing, heat, moisture, sunshine, and cold.”

+86 13513807403
SHARE:

CAAI Cable Features

Standard
Different from neutral supported cable, the CAAI cable’s standard is NTP 370.254, ICEA S-76-474.
Application
This type of overhead insulated cable is used for air networks of secondary distribution of low-cost electricity in urban and rural areas grid.

Specifications of CAAI Cable

SizeConstruction of ConductorXLPE InsulationApprox.Max. DC Resistance
No. of WireDia. Of WireApprox. Conductor Dia.Nominal ThicknessInsulation Dia.Weightat 20℃ of Conductor
(mm2)(No.)(mm)(mm)(mm)(mm)(kg/km)(Ω/km)
1671.724.81.147.0863.351.91
2572.1861.148.2891.751.2
3572.5571.149.28120.560.868
5072.9781.5211.04168.550.641
70192.2101.5213.04235.510.443
95192.5811.61.5214.64312.790.32
120192.88132.0317.06413.940.253
SizeConstruction of ConductorXLPE InsulationApprox.Max. DC Resistance
No. of WireDia. Of WireApprox. Conductor Dia.Nominal ThicknessInsulation Dia.Weightat 20℃ of Conductor
(mm2)(No.)(mm)(mm)(mm)(mm)(kg/km)(Ω/km)
2572.136.391.148.6794.821.3511
3572.527.561.149.84126.230.9651
5073.029.061.5212.1186.510.6755
7073.5710.711.5213.75249.230.4825
SizeConstruction of ConductorXLPE InsulationApprox.Max. DC Resistance
No. of WireDia. Of WireApprox. Conductor Dia.Nominal ThicknessInsulation Dia.Weightat 20℃ of Conductor
(mm2)(No.)(mm)(mm)(mm)(mm)(kg/km)(Ω/km)
1671.724.81.147.0863.351.91
2572.1861.148.2891.751.2
SizeApprox. Overall Dia.Approx. WeightSizeApprox. Overall Dia.Approx. Weight
(mm2)(mm)(kg/km)(mm2)(mm)(kg/km)
1×167.0863.41×16+16+ND2514.83196.2
1×258.2891.81×16+16+NA2516.47222.7
1×359.28120.62×16+16+ND2516.73259.6
1×5011.04168.62×25+16+ND2518.18316.4
1×7013.04235.52×16+16+NA2518.12286
1×9514.64321.82×25+16+NA2519.56342.8
1×12017.06413.92×35+16+NA2520.77400.5
1×15018.46490.73×16+NA2516.68284.9
2×1614.16126.73×25+NA2520.22370.1
2×2516.56183.53×16+16+ND2518.79322.9
2×3518.56241.13×16+16+NA2520.02349.4
3×1615.25190.13×25+16+NA2523.93499.1
3×3519.98361.72×35+ND2517.92309.5
3×5023.78505.72×35+NA2519.55336
3×7028.08706.53×35+NA2522.04456.5
4×1617.09253.43×35+16+ND2522.36494.6
4×2519.98367.13×35+16+NA2523.59521
1×16+ND2513.47131.83×35+2×16+NA2525.44585.5
1×16+NA2515.75158.23×50+NA3525.93631.9
1×25+NA2516.95186.63×50+16+NA2526.38663.8
2×16+ND2514.75195.13×50+16+NA3527.07696.4
2×16+NA2516.39221.53×50+25+NA3527.77724.7
2×25+ND2516.47251.93×70+NA3529.55832.8
2×25+NA2518.12278.43×70+16+NA5031.53957.5
2×25+1616.97246.93×70+25+NA5032.24985.8
2×35+1618.48305.73×95+16+NA5034.131188.3
3×25+1619.32339.83×95+NA5033.811124.9
3×35+1621.23426.23×95+16+NA7035.021252.1
3×120+1636.751306.33×120+16+NA7038.941555.5
Show more +