Concentric Cable Type USEB-90

The useb 90 cable is made up of 2 compacted aluminum conductors and the two cores are parallel, the insulation material of the core is RW90 XLPE, plain copper wire arranged in a spiral shape serving as a service and an overall PVC jacket covering. The neutral is served by the copper wire. The useb wire is designed for use in underground systems with voltages of 600 V or less. The cables are designed for installation underground, either directly buried or in duct systems. On termination poles and during storage, portions of the cable may be exposed to sunlight.

+86 13513807403
SHARE:

Type 61 Rubber Cable Features

Standard
CSA C22.2 No. 52, CSA C22.2 No. 38
Conductors
Class B compact 1350 aluminum.
Insulation
Low Density Polyethylene (LLDPE) or XLPE
Neutral Conductor
Annealed, plain copper wire
Binder/Separator Tape
Regarding this concentric electric cable, a separator tape is applied overtop the helically applied neutral conductor wires.
Jacket
With a reasonable concentric cable price, it has black PVC jacket.

Application of ACSR Conductor USEB-90 Cable

Overhead Power Transmission Lines: ACSR is the preferred choice for long-distance, high-voltage power transmission due to its excellent strength-to-weight ratio, which allows for longer spans between towers.

Distribution Lines: ACSR is widely used in both rural and urban areas for distributing electricity to homes and businesses. Its versatility makes it suitable for various voltage levels and environmental conditions.

Substation Busbars: In some cases, ACSR can be used as busbars in substations, although other materials like copper or aluminum are more common for this application.

Specifications of Concentric cable Type USEB-90

TWO CONDUCTOR TYPE USEB-90 – XLPE/PVC – FULL NEUTRAL – 600 VOLTS:

PHASE CONDUCTORSFULL NEUTRAL CONDUCTOROVERALL
SIZE (AWG OR kcmil)NO. OF WIRESINS. THKN. (mm)JACKET THKN. (mm)NO. OF WIRES x SIZEEQUIVALENTEFFECTIVEAPPROX. WEIGHTAMPACITY
(AWG)AWG SIZEDIAMETER THKN. X WIDTH (mm)(kg/km)
471.142.0311 x #16615 x 2245675
271.142.0317 x #16416 x 25632100
1191.42.0321 x #16317 x 28770115
1/0191.42.0326 x #16218 x 30916135
2/0191.42.0333 x #16119 x 321105150
3/0191.42.0326 x #141/021 x 351340175
4/0191.42.0333 x #142/022 x 371633205
250371.652.0326 x #123/025 x 411969230
300371.652.7921 x #1030030 x 472520260
350371.652.7925 x #1025030 x 492985280
500371.652.7934 x #1035033 x 553843350

TWO CONDUCTOR TYPE USEB-90 – XLPE/PVC – REDUCED NEUTRAL – 600 VOLTS:

PHASE CONDUCTORSREDUCED NEUTRAL CONDUCTOROVERALL
SIZE (AWG OR kcmil)NO. OF WIRESINS. THKN. (mm)JACKET THKN. (mm)NO. OF WIRES x SIZE(AWG)EQUIVALENT AWG SIZEEFFECTIVE DIAMETER THKN. x WIDTH(mm)APPROX. WEIGHT (kg/km)AMPACITY
471.142.037 x #16815 x 2240575
271.142.0311 x #16616 x 25557100
1191.42.0313 x #16517 x 28670115
1/0191.42.0317 x #16418 x 30804135
2/0191.42.0321 x #16319 x 32956150
3/0191.42.0326 x #16220 x 341143175
4/0191.42.0321 x #14124 x 391366205
250371.652.0326 x #141/024 x 401651230
300371.652.7921 x #124/029 x 462090260
350371.652.7926 x #123/029 x 482436280
500371.652.7925 x #1025033 x 553392350
Show more +