Leave Us a Message
Whether you require a quote, have questions or need assistance, our team is ready to provide expert guidance.
Contact Form

Concentric Cable Type USEB-90

The useb 90 cable is made up of 2 compacted aluminum conductors and the two cores are parallel, the insulation material of the core is RW90 XLPE, plain copper wire arranged in a spiral shape serving as a service and an overall PVC jacket covering. The neutral is served by the copper wire. The useb wire is designed for use in underground systems with voltages of 600 V or less. The cables are designed for installation underground, either directly buried or in duct systems. On termination poles and during storage, portions of the cable may be exposed to sunlight.

+86 13513807403
SHARE:

Type 61 Rubber Cable Features

Standard
CSA C22.2 No. 52, CSA C22.2 No. 38
Conductors
Class B compact 1350 aluminum.
Insulation
Low Density Polyethylene (LLDPE) or XLPE
Neutral Conductor
Annealed, plain copper wire
Binder/Separator Tape
Regarding this concentric electric cable, a separator tape is applied overtop the helically applied neutral conductor wires.
Jacket
With a reasonable concentric cable price, it has black PVC jacket.

Application of ACSR Conductor USEB-90 Cable

Overhead Power Transmission Lines: ACSR is the preferred choice for long-distance, high-voltage power transmission due to its excellent strength-to-weight ratio, which allows for longer spans between towers.

Distribution Lines: ACSR is widely used in both rural and urban areas for distributing electricity to homes and businesses. Its versatility makes it suitable for various voltage levels and environmental conditions.

Substation Busbars: In some cases, ACSR can be used as busbars in substations, although other materials like copper or aluminum are more common for this application.

Specifications of Concentric cable Type USEB-90

TWO CONDUCTOR TYPE USEB-90 – XLPE/PVC – FULL NEUTRAL – 600 VOLTS:

PHASE CONDUCTORS FULL NEUTRAL CONDUCTOR OVERALL
SIZE (AWG OR kcmil) NO. OF WIRES INS. THKN. (mm) JACKET THKN. (mm) NO. OF WIRES x SIZE EQUIVALENT EFFECTIVE APPROX. WEIGHT AMPACITY
(AWG) AWG SIZE DIAMETER THKN. X WIDTH (mm) (kg/km)
4 7 1.14 2.03 11 x #16 6 15 x 22 456 75
2 7 1.14 2.03 17 x #16 4 16 x 25 632 100
1 19 1.4 2.03 21 x #16 3 17 x 28 770 115
1/0 19 1.4 2.03 26 x #16 2 18 x 30 916 135
2/0 19 1.4 2.03 33 x #16 1 19 x 32 1105 150
3/0 19 1.4 2.03 26 x #14 1/0 21 x 35 1340 175
4/0 19 1.4 2.03 33 x #14 2/0 22 x 37 1633 205
250 37 1.65 2.03 26 x #12 3/0 25 x 41 1969 230
300 37 1.65 2.79 21 x #10 300 30 x 47 2520 260
350 37 1.65 2.79 25 x #10 250 30 x 49 2985 280
500 37 1.65 2.79 34 x #10 350 33 x 55 3843 350

TWO CONDUCTOR TYPE USEB-90 – XLPE/PVC – REDUCED NEUTRAL – 600 VOLTS:

PHASE CONDUCTORS REDUCED NEUTRAL CONDUCTOR OVERALL
SIZE (AWG OR kcmil) NO. OF WIRES INS. THKN. (mm) JACKET THKN. (mm) NO. OF WIRES x SIZE(AWG) EQUIVALENT AWG SIZE EFFECTIVE DIAMETER THKN. x WIDTH(mm) APPROX. WEIGHT (kg/km) AMPACITY
4 7 1.14 2.03 7 x #16 8 15 x 22 405 75
2 7 1.14 2.03 11 x #16 6 16 x 25 557 100
1 19 1.4 2.03 13 x #16 5 17 x 28 670 115
1/0 19 1.4 2.03 17 x #16 4 18 x 30 804 135
2/0 19 1.4 2.03 21 x #16 3 19 x 32 956 150
3/0 19 1.4 2.03 26 x #16 2 20 x 34 1143 175
4/0 19 1.4 2.03 21 x #14 1 24 x 39 1366 205
250 37 1.65 2.03 26 x #14 1/0 24 x 40 1651 230
300 37 1.65 2.79 21 x #12 4/0 29 x 46 2090 260
350 37 1.65 2.79 26 x #12 3/0 29 x 48 2436 280
500 37 1.65 2.79 25 x #10 250 33 x 55 3392 350