PVC Insulated And Sheathed Cable

Power cables with PVC insulation and sheath are suitable for distribution lines with A.C.50Hz and rated voltages within 1kV. With the characteristics of stable capability, advanced technology, a wide range of material resources, low prices, good flexibility, and convenience of installation and maintenance. The pvc insulated and sheathed cable has good chemical stability along with acid and alkali resistance, salt resistance, oil resistance, solvent resistance, and flame resistance.

+86 13513807403
SHARE:

PVC Insulated And Sheathed Cable Features

Standard
IEC, BS, VDE, AS/NZS, ICEA, JIS, designing and manufacturing special power cable according to the other standards required by the customer.
Working Temperature
Different fromlow voltage xlpe cable, the working temperature of PVC insulated and sheathed cable is not more than 70 °C.
Max. Temperature of Cable Conductor
not more than 165°C.
Ambient Temperature
When laying the cable, is not lower than 0°C.

Specifications of PVC Insulated And Sheathed Cable

Cross Section of ConductorNo. of WiresThickness of InsulationUnarmouredArmoured
Thickness of SheathOverall Dia.Approx.Net WeightThickness of BeddingThickness of Al TapeThickness of SheathOverall Dia.Approx.Net Weight
Al ConductorCu ConductorAl ConductorCu Conductor
mm²mmmmmmkg/kmkg/kmmmmmmmmmkg/kmkg/km
1.510.81.45.851
2.510.81.46.264
4111.47.188
6711.47.878114
10711.48.69615910.51.813.4234295
16711.49.612322210.51.814.4274370
2571.21.411.217232810.51.816344496
3571.21.412.220942810.51.817393606
50191.41.413.927156510.51.818.7478764
70191.41.515.935681810.51.820.55821020
95191.61.518471104110.51.822.67171291
120371.61.619.6563130710.51.8248221545
150371.81.621.3684159210.51.825.49521857
1853721.723.9840198510.51.827.911362236
240612.21.8271071253310.51.93114042877
300612.41.929.6131731621.20.52.134.317223551
400612.6233.2166641201.20.52.237.621144488
500612.82.237.5208951631.20.52.342.125925683
630612.82.341.2258164471.40.52.446.331847060
Number of CoresCross-Section of ConductorNo. Of WiresThickness of InsulationThickness of SheathOverall DiameterApprox. Net Weight
Al ConductorCu Conductor
mm²mmmmmmkg/kmkg/km
Three Cores3×35161.21.821.96011280
3×50181.41.826.58291732
3×70181.41.929.210672367
3×95361.6232.914092317
3×120361.62.136.217053983
3×150361.82.238.820454872
3×1853622.444.825966077
3×240602.22.651.533537953
3×300602.42.754.960699820
Four Cores with Reduced Neutral3×35+167-161.2-11.825.57641107
3×50+2518-161.4-1.21.928.79821410
3×70+3518-161.4-1.223212781733
3×95+5036-181.6-1.42.237.817112656
3×120+7036-181.6-1.42.340.520653137
3×150+7036-181.8-1.42.444.824803660
3×185+9536-362-1.62.649.730864345
3×240+12060-362.2-1.62.85638945441
3×300+15060-361.4-1.82.960.348346494
Four Cores4×25161.21.822.56441286
4×35161.21.824.67991696
4×50181.41.828.610712275
4×70181.4231.613873120
4×95361.62.135.918504262
4×120361.62.238.822095247
4×150361.82.343.127146483
4×1853622.548.734038045
4×240602.22.753.6429010422
4×300602.42.958.8530212969
Number of CoresCross-Section of ConductorNo. Of WiresThickness of InsulationThickness of SheathOverall DiameterApprox. Net Weight
Al ConductorCu Conductor
mm²mmmmmmkg/kmkg/km
Three Cores3×10711.816.6281465
3×16711.818.7387679
3×2571.21.822.2536996
3×3571.21.824.46651311
3×50191.41.928.18631729
3×70191.4232.311532480
3×95191.62.137.115633301
3×120371.62.340.418504040
3×150371.82.443.922585000
3×1853722.549.228196151
3×240612.22.855.935778040
3×300612.4362.144139955
3×400612.63.269.3551212705
Four Cores4×10711.818.1343589
4×16711.820.5487874
4×2571.21.824.36771291
4×3571.21.826.88211681
4×50191.4231.211182273
4×70191.42.135.814943264
4×95191.62.341.219934312
4×120371.62.444.823705291
4×150371.82.548.729596615
4×1853722.754.736018044
4×240612.2362.1459610547
4×300612.43.269.1561413004
Cross Section of ConductorNo. of WiresThickness of InsulationThickness of Inner SheathThickness of Steel TapeNo./Dia. Of Steel WiresThickness of SheathOverall DiameterApprox. Net Weight
STASWA
STASWASTASWASTASWAAl ConductorCu ConductorAl ConductorCu Conductor
mm²mmmmmmNo./mmmmmmmmmmkg/kmkg/kmkg/kmkg/km
Three Cores
3×35161.210.238/1.61.81.924.728.2912159114472126
3×50181.410.246/1.61.9229.332.81202210518422745
3×70181.41.20.241/2.022.232.537.11520282024753775
3×95361.61.20.546/2.02.12.336.540.82241404929894797
3×120361.61.20.550/2.02.22.439.844.12617489534355713
3×150361.81.20.543/2.52.32.542.447.83019584642587085
3×1853621.40.550/2.52.52.748.854.23783726452198700
3×240602.21.60.558/2.52.82.95661.347909390644411044
3×300602.41.60.561/2.52.93.159.364.7559411345745813209
Four Cores with Reduced Neutral
3×35+167-161.2-110.243/1.61.9228.531.31107152817052469
3×50+2518-161.4-1.21.20.240/2.022.132.236.11410204423263388
3×70+3518-161.4-1.21.20.244/2.022.235.239.31733280127624285
3×95+5036-181.6-1.41.20.541/2.52.32.542.546.32656382038165925
3×120+7036-181.6-1.41.40.545/2.52.42.645.649.43137477743917103
3×150+7036-181.8-1.41.40.549/2.52.62.749.953.63660570950438272
3×185+9536-362-1.61.40.555/2.52.62.954.558.53445717159029987
3×240+12060-362.2-1.61.60.562/2.52.93.161.665.354419272717412552
3×300+15060-361.4-1.81.60.567/2.53.83.265.969.6649411546835515067
Four Cores
4×25161.210.238/1.61.81.925.328934157614502092
4×35161.210.241/1.61.81.927.430.21120201716812578
4×50181.410.239/2.022.131.635.61454265823363540
4×70181.41.20.543/2.02.12.236.3392183391628404573
4×95361.61.20.550/2.02.32.440.644.12748516035455957
4×120361.61.40.542/2.52.42.543.947.23237621443347372
4×150361.81.40.548/2.52.52.648.3523853762251488917
4×1853621.60.554/2.52.72.854.357.647569323613210774
4×240602.21.60.559/2.52.9359.262.9577411906737413506
4×300602.41.60.565/2.533.264.368.1692214589862416291
Cross Section of ConductorNo. of WiresThickness of InsulationThickness of Inner SheathThickness of Steel TapeNo./Dia. Of Steel WiresThickness of SheathOverall DiameterApprox. Net Weight
STASWA
STASWASTASWASTASWAAl ConductorCu ConductorAl ConductorCu Conductor
mm²mmmmmmNo./mmmmmmmmmmkg/kmkg/kmkg/kmkg/km
Three Cores
3×107110.235/1.251.81.819.421.54946799881172
3×167110.232/1.61.81.821.524.360489510511343
3×2571.210.238/1.61.81.82527.9791125213291790
3×3571.210.242/1.61.81.927.230.2950159515512196
3×50191.41.10.239/2.022.131.335.21213207921282994
3×70191.41.20.545/2.02.12.235.640.11567289426784005
3×95191.61.30.542/2.52.32.44246.22449418836895428
3×120371.61.30.545/2.52.42.545.349.62823501441746364
3×150371.81.40.549/2.52.52.748.953.23327606947957537
3×1853721.50.556/2.52.72.854.558.74038737156869019
3×240612.21.60.563/2.52.93.161.465.249949457686211325
3×300612.41.70.570/2.53.23.367.971.7602211564810113643
3×400612.61.90.562/3.153.43.675.480.57350145431053517728
Four Cores
4×107110.239/1.251.81.820.92355279810731319
4×167110.235/1.61.81.823.326.1723111012131601
4×2571.210.242/1.61.81.927.230.2959157315592173
4×3571.210.237/2.01.9229.733.61140200020062866
4×50191.41.20.244/2.02.12.234.638.41524267925413696
4×70191.41.20.550/2.02.32.340.543.72338410731874956
4×95191.61.20.546/2.52.42.645.950.22955527443256644
4×120371.61.40.551/2.52.62.75054.23466638745687888
4×150371.81.40.555/2.52.72.853.858.14144780057729428
4×1853721.60.562/2.52.9360.264.549879430682211266
4×240612.21.60.570/2.53.13.367.771.5616112111823314184
4×300612.41.60.561/3.153.43.574.778.87346147351030517694
Show more +