Email Us
acsr wire
acsr cable
aluminium conductor steel reinforced
acsr aluminum conductor steel reinforced

Aluminum Conductor Steel Reinforced (ACSR)

Steel - cored aluminium stranded wire, it could also be described as ACSR Conductor or ACSR Aluminium Conductor or acsr aluminium conductor steel reinforced etc.. Steel - cored aluminium stranded wire has the same structure as the aluminum conductor alloy reinforced (ACAR) , except that the aluminum wires outside the steel core have been changed to alloy wires . ACSR aluminium conductor steel reinforced mainly used to transmit electricity in overhead transmission lines. And the aluminium steel reinforced conductor(ACSR) is made of twisted aluminum wire and steel wire. Among them, the steel core mainly plays the role of increasing strength, and the aluminum wire mainly plays the role of conveying electric energy. ACSR Aluminium Conductors mainly has ASTM standards (such as ACSR Raven conductor, ACSR Cardinal conductor etc. ), BS standards (such as ACSR Rabbit conductor , ACSR Fox Conductor etc.), IEC standards ( Such as ACSR 100mm2, ACSR120mm2 etc.), DIN standards( such as ACSR 120/20mm2, ACSR 150/25mm2 etc.), CSA standards( such as ACSR Ostrich conductor, ACSR Hawk conductor etc.)  and other production standards. Because of its low comprehensive cost, large transmission capacity, small power loss and other characteristics, acsr aluminum conductor steel reinforced has become the most commonly used material for overhead wire. Honrey is a professional acsr cable manufacturer.

Aluminum Conductor Steel Reinforced (ACSR) Features

01.
STANDARD

IEC61089; DIN48204; CSA C49; ASTM B230, B231, B498; BS215, BS EN50182, BS4565

02.
Contruction

Aluminum wires and the steel cores are concentrically stranded and wrapped helically around a central wire.

03.
Application

This type of bare conductor cable is suitable for use in all practical spans on wood poles, transmission towers,and other structures.

04.
Greased

Greased aluminum conductor steel reinforced can be supplied.

Aluminum Conductor Steel Reinforced Advantages

01.
Durability

The aluminum conductor steel reinforced is strong, durable and economical, making them an ideal choice for many industries.

02.
Strength

The aluminium conductor steel reinforced is widely used in overhead power transmission and distribution lines due to their high strength to weight ratio.

03.
Resistance

The acsr wire is resistant to corrosion and provide excellent electrical conductivity.

04.
High-quality Material

The professional acsr wire manufacturer provides complete solutions for ACSR wire and cable projects with the highest quality materials.


Why Aluminum Conductor Steel Reinforced Are Used in Transmission and Distribution Systems?


Aluminium conductor steel reinforced (ACSR) cables are used in transmission and distribution systems due to their strength and durability. They are produced by a low-cost acsr cable manufacturer, making them an economical choice for long-distance transmission and distribution networks. The steel core also helps to improve the overall strength and flexibility of the cable, allowing for even weight distribution and easy installation. The aluminium steel reinforced conductor is also corrosion-resistant and require minimal maintenance, making them a reliable option for outdoor power distribution.




Aluminum Conductor Steel Reinforced Common Problems and Their Solutions

Aluminium conductor steel reinforced (ACSR) cables are manufactured by specialist acsr cable manufacturers and are used in various electrical applications. Common problems with aluminium steel reinforced conductor include increased electrical resistance due to corrosion, abrasion and other environmental factors. Solutions to these problems include regular inspection of the cables, improved sealing and insulation, and the use of corrosion-resistant steel. Additionally, using specialized coatings and insulation materials can help reduce electrical resistance and ensure long service life.




What are the components of ACSR?

Aluminum Conductor Steel Reinforced ACSR conductor is made of twisted aluminum wire wrapped around a galvanized steel core. The galvanized steel core used for ACSR conductor is  zinc-coated steel , at the same time , the steel core is also divided into different types. The thickness of zinc layer and the breaking load of steel core  required by different production standards are different. As for the aluminum wires , diffierent size ACSR Conductor , the number of aluminum wires and the diameter of single strand are different .



Specifications of Aluminum Conductor Steel Reinforced (ACSR)

IEC Standard
DIN Standard
CSA C Standard
ASTM Standard
BSStandard
Code NumberAreaNumber of WiresWire Dia.DiameterLinear MassA1/S1 A ConductorA1/S2 A ConductorA1/S3 A ConductorMax.D.C. Resistance
at 20℃
Alum.SteelTotalAI.St.Alum.SteelCoreCond.
Rated StrengthRated StrengthRated Strength
mm²mm²mm²mm²

mmmmmmmmkg/kmkN

Ω/km
16162.6718.7611.841.841.645.5364.66.086.456.831.7934
25254.1729.2612.32.32.36.91100.99.139.7110.251.1478
40406.6746.7612.912.912.918.74161.514.415.3316.20.7174
636310.573.5613.663.663.6611254.421.6322.3724.150.4555
10010016.7117614.614.614.6113.8403.834.3335.538.330.2869
1251256.941321812.972.972.9714.9397.929.1730.1431.040.2304
12512520.41452672.471.925.7715.7503.945.6948.5451.390.231
1601608.891691813.363.363.3616.8509.336.1837.4238.670.18
16016026.11862672.82.186.5317.7644.957.6961.3464.990.1805
20020011.12111813.763.763.7618.8636.744.224546.890.144
20020032.62332673.132.437.319.8806.270.1374.6978.930.1444
25025024.62752273.82.116.3421.6880.668.7272.1675.60.1154
25025040.72912673.52.728.1622.21007.787.6793.3798.660.1155
31531521.83374572.991.995.9723.91039.379.0382.0885.130.0917
31531551.33662673.933.059.1624.91269.7106.83114.02121.20.0917
40040027.74284573.362.246.7326.91320.198.36102.23106.10.0722
40040051.94525473.073.079.2127.61510.3123.04130.3137.560.0723
45045031.14814573.572.387.1428.51485.2107.47111.82115.870.0642
45045058.35085473.263.269.7729.31699.1138.42146.58154.750.0643
50050034.65354573.762.517.5230.11650.2199.41124.25128.740.0578
50050064.85655473.433.4310.330.91887.9153.8162.87171.940.0578
56056038.75994573.982.657.9631.81848.2133.74139.16144.190.0516
56056070.963154193.632.1810.932.72103.4172.59182.52192.450.0516
63063043.66744574.222.818.4433.82079.2150.45156.55162.210.0459
63063079.871054193.852.3111.634.72366.3191.77202.94213.310.0459
71071049.17594574.482.998.9635.92343.2169.56176.43182.810.0407
71071089.980054194.092.4512.336.82666.8216.12228.71240.410.0407
80080034.68357273.762.517.5237.62480.2167.41172.25176.740.0361


Code NumberCalculated Cross SectionNo./Dia. Of Stranding WiresOverall
Diameter
Linear MassNominal Breaking LoadMax.D.C. Resistance
at 20℃
Al./StAl.SteelTotalAlum.Steel-Alum.SteelTotal

mm²mm²mm²mm²mmmmmmkg/kmkg/kmkg/kmdaNΩ/km
16/2.515.32.517.86/1.801/1.805.44220625951.878
25/423.8427.86/2.251/2.256.86532979201.2002
35/634.35.7406/2.701/2.708.1944614012650.8352
44/324431.775.714/2.007/2.4011.212225037245000.6573
50/848.3856.36/3.201/3.209.61326419617100.5946
50/3051.229.88112/2.337/2.3311.714123737843800.5643
70/1269.911.481.326/1.857/1.4411.71939128426800.413
95/1594.415.3109.726/2.157/1.6713.626012338335750.3058
95/5596.556.3152.812/3.207/3.201626644671279350.2992
105/7510675.5181.514/3.109/2.2517.5292599891108450.2735
120/2012119.8141.426/2.447/1.9015.533615849445650.2374
120/7012271.3193.312/3.67/3.6018337564901100000.2364
125/3012829.8157.730/2.337/2.3316.335323859157600.2259
150/2514924.2173.126/2.707/2.1017.141119460555250.1939
170/4017240.1211.930/2.707/2.7018.947531979476750.1682
185/3018429.8213.626/3.007/2.331950723974666200.1571
210/3520934.1243.226/3.207/2.4920.357727385074900.138
210/5021249.5261.630/3.007/3.002158739498193900.1362
230/3023129.8260.724/3.507/2.332163823987773100.1249
240/4024339.5282.526/3.457/2.6821.967131698786400.1188
265/3526434.1297.824/3.747/2.4922.4728274100283050.1094
300/5030449.5353.726/3.867/3.0024.58403961236107000.09487
305/4030539.5344.154/2.687/2.6824.1843317116099400.0949
340/3033929.8369.148/3.007/2.3325938242118092900.08509
380/5038249.5431.554/3.007/3.002710563971453123100.08509
385/3538634.1420.148/3.207/2.4926.710672771344104800.07573
435/5543459.3490.654/3.207/3.2028.812034501653136450.07478
450/4044939.5488.248/3.457/2.6828.712413201561120750.06656
490/6549063.6553.954/3.407/3.4030.613565101866153100.06434
495/3549434.1528.245/3.747/2.4929.913632831646121800.05846
510/4551045.3555.548/3.687/2.8730.714133651778136650.05655
550/7055071.3621.354/3.607/3.6032.415205722092170600.05259
560/5056249.5611.248/3.867/3.0032.215534011954148950.0514
570/4056639.5610.345/4.027/2.6832.215633251888139000.05108
650/4569945.3653.545/4.307/2.8734.417913722163155520.0442
680/8567986764.854/4.0019/2.403618687022570210400.0426
Code NameKCMIL or AWGCross SectionSteel RatioStranding WiresDia.of CoreOverall Dia.Linear MassRated
Tensile
Strength
Max.D.C. Resistance
at 20℃
Alum. WireSteel Wire
Alum.TotalNo.Dia.No.Dia.
 --mm²mm²%-mm- mmmmmmkg/kmkNΩ/km
Wren89.379.761761.3311.331.333.9933.83.293.43
Warbler710.5512.321761.511.51.54.542.84.142.72
Turkey613.315.511761.6811.681.685.0453.85.192.158
Thrush516.7719.571761.8911.891.895.6767.96.561.711
Swan421.1524.681762.1212.122.126.3685.68.151.357
Swallow326.6631.111762.3812.382.387.14107.9101.076
Sparrow233.6339.221762.6712.672.678.0113612.40.8534
Robin142.4149.4817631339171.615.30.6766
Raven1/053.5162.431763.3713.373.3710.11216.518.90.5363
Quail2/067.4478.671763.7813.783.7811.3427323.50.4255
Pigeon3/085.0399.211764.2514.254.2512.7534429.60.3375
Penguin4/0107.2125.11764.7714.774.7714.3143437.30.2676
Partridge266.8135.2157.216262.5772616.28546500.2136
Owl266.8135.2152.81365.3671.795.3716.0950942.30.2123
Waxwing266.8135.2142.76183.0913.093.0915.4543131.20.213
Piper300152187.523302.5472.547.6217.7869867.80.1898
Ostrich300152176.716262.7372.126.3617.2861456.30.19
Phoebe300152160.56183.2813.283.2816.448535.20.1895
Oriole336.4170.5210.223302.6972.698.0718.83783760.1693
Linnet336.4170.5198.316262.8972.256.758.3168962.40.1694
Merlin336.4170.5179.96183.4713.473.4717.3552239.30.169
Lark397.5201.4248.323302.9272.928.7620.4492488.60.1433
Ibis397.5201.4234.116263.1472.447.3219.8881371.50.1434
Chickadee397.5201.4212.66183.7713.773.7718.8564245.40.143
Hen477241.729823303.273.29.622.411091030.1194
Hawk477241.7281.216263.4472.688.0421.897786.10.1195
Toucan477241.7265.510223.7472.086.2421.285468.90.1193
Pelican477241.7255.16184.1314.134.1320.6577154.50.1192
Heron500253.4312.523303.2873.289.8422.9611631080.1139
Eagle556.5282347.823303.4673.4610.3824.2212951200.1023
Dove556.5282327.916263.7272.898.6723.5511391000.1024


Code NameSizeNo./Dia.of Stranding WiresApprox. Overall Dia.Approx. WeightCode NameSizeNo./Dia.of Stranding WiresApprox. Overall Dia.Approx. Weight
AWG or MCMAluminumSteelAWG or MCMAluminumSteel
No./mmNo./mmmmkg/kmNo./mmNo./mmmmkg/km
Turkey66/1.681/1.685.0454Starling715.526/4.217/3.2826.681466
Swan46/2.121/2.126.3685Redwing715.530/3.9219/2.3527.431653
Swanate47/1.961/2.616.53100Tern795.045/3.387/2.2527.031333
Sparrow26/2.671/2.678.01136Condor795.054/3.087/3.0827.721524
Sparate27/2.471/3.308.24159Cuckoo795.024/4.627/3.0827.741524
Robin16/3.001/3.009.00171Drake795.026/4.447/3.4528.111628
Raven1/06/3.371/3.3710.11216Coot795.036/3.771/3.7726.411198
Quail2/06/3.781/3.7811.34273Mallard795.030/4.1419/2.4828.961838
Pigeon3/06/4.251/4.2512.75343Ruddy900.045/3.597/2.4028.731510
Penguin4/06/4.771/4.7714.31433Canary900.054/3.287/3.2829.521724
Waxwing266.818/3.091/3.0915.45431Rail954.045/3.707/2.4729.611601
Partridge266.826/2.577/2.0016.28546Catbird954.036/4.141/4.1428.951438
Ostrich300.026/2.737/2.1217.28614Cardinal954.054/3.387/3.3830.421829
Merlin336.418/3.471/3.4717.5544Ortlan1033.545/3.857/2.5730.811734
Linnet336.426/2.897/2.2518.31689Tanger1033.536/4.301/4.3030.121556
Oriole336.430/2.697/2.6918.83784Curlew1033.554/3.527/3.5231.681981
Chickadee397.518/3.771/3.7718.85642Bluejay1113.045/4.007/2.6631.981868
Brant397.524/3.277/2.1819.61762Finch1113.054/3.6519/2.1932.852130
Ibis397.526/3.147/2.4419.88814Bunting1192.545/4.147/2.7633.122001
Lark397.530/2.927/2.9220.44927Grackle1192.554/3.7719/2.2733.972282
Pelican477.018/4.141/4.1420.70771Bittern1272.045/4.277/2.8534.172134
Flicker477.024/3.587/2.3921.49915Pheasant1272.054/3.9019/2.3435.102433
Hawk477.026/3.447/2.6721.79978Skylark1272.036/4.781/4.7833.421917
Hen477.030/3.207/3.2022.401112Dipper1351.545/4.407/2.9235.162266
Osprey556.518/4.471/4.4722.35899Martin1351.554/4.0219/2.4136.172585
Parakeet556.524/3.877/2.5823.221067Bobolink1431.045/4.537/3.0236.242402
Dove556.526/3.727/2.8923.551140Plover1431.054/4.1419/2.4837.242738
Eagle556.530/3.467/3.4624.211298Nuthatch1510.545/4.657/3.1037.202534
Peacock605.024/4.037/2.6924.201160Parrot1510.554/4.2519/2.5538.252890
Squab605.026/3.877/3.0124.511240Lapwing1590.045/4.777/3.1838.162667
WoodDuck605.030/3.617/3.6125.251411Falcon1590.054/4.3619/2.6239.263042
Teal605.030/3.6119/2.1625.241399High Strength Stranding
Kingbird636.018/4.781/4.7823.881028Grouse808/2.541/4.249.32222
Rook636.024/4.147/2.7624.841219Petrel101.812/2.347/2.3411.71378
Grosbeak636.026/3.977/3.0925.151302Minorca110.812/2.447/2.4412.22412
Scoter636.030/3.707/3.7025.881484Leghorn134.612/2.697/2.6913.46500
Egret636.030/3.7019/2.2225.901470Guinea15912/2.927/2.9214.63590
Swift636.036/3.381/3.3823.62958Dotterel176.912/3.087/3.0815.42657
Flamingo666.624/4.237/2.8225.401278Dorking190.812/3.207/3.2016.03709
Gannet666.626/4.077/3.1625.761365Brahma203.216/2.8619/2.4818.141007
Code NameNominal Cross SectionNo./Dia. of Stranding WiresCalculated Cross SectionApprox.Overall Dia.Approx. WeightCode NameNominal Cross SectionNo./Dia. of Stranding WiresCalculated Cross SectionApprox.Overall Dia.Approx. Weight
Al.St.Al.St.Total.
Al.St.Al.St.Total.

-mm2No./mmNo./mmmm2mm2mm2mmkg/km-mm2No./mmNo./mmmm2mm2mm2mmkg/km
Squirrel206/2.111/2.1120.983.5024.486.3384.85Batang30018/4.787/1.68323.1015.52338.6024.161012.00
Gopher256/2.361/2.3626.244.3730.627.08106.10Bison35054/3.007/3.00381.7049.48431.2027.001443.00
Weasel306/2.591/2.5931.615.2736.887.77127.80Zebra40054/3.187/3.18428.9055.59484.5028.621022.00
Ferret406/3.001/3.0042.417.0749.489.00171.50Eik45030/4.507/4.50447.00111.30588.3031.502190.00
Rabbit506/3.351/3.3552.888.8161.7010.05213.80Camel45054/3.357/3.35476.0061.70537.3030.151800.00
Mink606/3.661/3.6663.1210.5273.6410.98255.30Mole106/1.501/1.5010.621.7712.394.5043.00
Skunk6012/2.597/2.5963.2336.88100.1012.95463.60Fox356/2.791/2.7936.666.1142.778.37149.00
Horse7012/2.797/2.7973.3742.80116.2013.95538.10Beaver756/3.391/3.3975.0012.5087.5011.97304.00
Raccoon706/4.091/4.0978.8413.1491.9812.27318.90Otter856/4.221/4.2283.9413.9997.9312.66339.00
Dog1006/4.727/1.57105.0013.55118.5014.15394.30Cat956/4.501/4.5095.4015.90111.3013.50386.00
Wolf15030/2.597/2.59158.1036.88194.9018.13725.70Hare1056/4.721/4.7214.1617.50105.0014.16424.00
Dingo15018/3.351/3.35158.708.81167.5016.75505.70Hyena1057/4.397/1.93105.9520.48126.4314.57450.00
Lynx17530/2.797/2.79183.4042.80226.2019.53842.40Leopard1306/5.287/1.75131.3716.84148.2115.81492.00
Caracal17518/3.611/3.61184.3010.24194.5018.05587.60Coyote13026/2.547/1.91131.7420.06131.7415.89520.00
Panther20030/3.007/3.00212.1049.48261.5021.00973.80Couqar13018/3.051/3.05131.587.31138.8915.25419.00
Jaguar20018/3.861/3.86210.6011.70222.3019.30671.40Giger13030/2.367/2.36131.2230.62161.8416.52602.00
Bear25030/3.357/3.35264.4061.70326.1023.451214.00Lion24030/3.187/3.18238.3055.60293.9022.261094.00
Goat30030/3.717/3.71324.3075.67400.0025.971489.00Moose52854/3.537/3.53528.5068.50597.0031.771996.00


Aluminium Steel Reinforced Conductor FAQs

  • Is it possible to utilize aluminum steel reinforced conductor for both indoor and outdoor applications in a commercial building?

    Steel core aluminum stranded wire is suitable for overhead transmission lines, not suitable for indoor use.

  • Does aluminium steel reinforced conductor work for residential and commercial applications?
    1. The power cable in the house should be copper conductor. Therefore, residential should use copper wire, should not use steel core aluminum stranded wire.

    2. The selection and laying of fire fighting lines should meet the needs of continuous power supply or signal transmission in case of fire. All fire lines shall be copper conductors or cables. Therefore, the fire load in the building (such as fire fans, fire elevators, fire pumps, emergency lighting, etc.) should be copper wire.) , do not use steel core aluminum stranded wire.    


  • How long does an aluminium steel reinforced conductor last, and how often should it be replaced?

    Under normal circumstances, the service life of wire and cable is not less than 70 years. The service life of steel core Al strand wire is affected by the service environment. For example, in the coastal salt spray area, the corrosion of aluminum is greatly affected, and the cable life is greatly shortened.  

  • What is the ultimate temperature for an aluminum steel reinforced conductor?

    The maximum temperature of steel core Al strand and steel core Al strand during normal operation shall not exceed 70℃ (+90℃ is used for large span).

Products

Gallary of Aluminum Conductor Steel Reinforced (ACSR)

gallary of acsr
gallary of aluminum conductor steel reinforced
gallary of aluminum conductor steel reinforced acsr
Leave a Message to Honrey

As a one-stop cable procurement service supplier of electrical wires & cables, Honrey will be at your service.

Related Bare Conductor

Honrey Electrical Cable News

Contact Us EMAIL
sales@honreycable.com
PHONE
0371-61288078
ADDRESS
No.195, Funiu Road, Zhengzhou City, Henan Province, China