Email Us
mv armoured cable
armoured xlpe cable

Armoured Xlpe Medium Voltage Cable

The three cores Medium Voltage Insulated power cables with insulation of cross-linked polyethylene (XLPE) are designed for transfer and distribute of electrical power with nominal voltage Uo/U 3.6/6kV, 6.35/11kV, 8.7/15kV, 12/20kV, 19/33kV, 26/35kV and frequency 50Hz in urban and district electrical networks and for electrical supply of transformer's substations, small and medium industrial plants. This mv armoured cable is suitable for use in distribution installations, electric power stations and industrial systems. 

Armoured Xlpe Medium Voltage Cable Features

01.
STANDARD

IEC60502, designing and manufacturing special power cable according to the other standards required by the customers.

02.
Operating Temperature of Conductor

The operating temperature of this mv power cable is 90 degrees.

03.
Max. Temperature for Conductor

no more than 250 degrees.


Specifications of Armoured Xlpe Medium Voltage Cable

1)3.6/6(7.2)kV,3.6/6.6(7.2)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable
2)6/10(12)kV,6.35/11(12)kV,,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable
3)8.7/10(15)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable
4)12/20(24)kV, 12.7/22(24)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable
5)18/30(36)kV,19/33(36)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable
No.X Nominal Cross Section of ConductorNominal Diameter of ConductorNominal Thickness of InsulationNominal Thickness of Copper Tape ScreenNominal Thickness of Inner SheathNominal Thickness of Steel Tape ArmouringNominal Thickness of PVC SheathApprox. Overall DiameterApprox. Weight
Al ConductorCu Conductor
No. X mm2mmmmmmmmmmmmmmkg/mkg/m
3 X 2562.50.11.20.21.937.91.872.32
3 X 356.92.50.11.30.5241.52.12.73
3 X508.22.50.11.30.5244.32.373.22
3 X 709.72.50.11.40.52.147.92.774
3 X 9511.32.50.11.40.52.251.63.214.91
3 X 12012.82.50.11.50.52.455.43.695.84
3 X 15014.22.50.11.50.52.558.64.156.85
3 X 18515.92.50.11.50.52.662.54.738.11
3 X 24018.32.60.11.60.52.768.55.6210.05
3 X 30020.42.80.11.70.52.974.56.5512.11
3 X 40023.230.11.90.83.283.68.7815.86
3 X 50026.43.20.12.10.83.49310.5218.85


No.X Nominal Cross Section of ConductorNominal Diameter of ConductorNominal Thickness of InsulationNominal Thickness of Copper Tape ScreenNominal Thickness of Inner SheathNominal Thickness of Steel Tape ArmouringNominal Thickness of PVC SheathApprox. Overall DiameterApprox. Weight
Al ConductorCu Conductor
No. X mm2mmmmmmmmmmmmmmkg/mkg/m
3 X 2563.40.11.30.5243.42.162.61
3 X 356.93.40.11.30.5245.42.362.99
3 X508.23.40.11.40.52.248.82.693.54
3 X 709.73.40.11.50.52.352.43.14.33
3 X 9511.33.40.11.50.52.456.13.565.26
3 X 12012.83.40.11.50.52.559.54.046.19
3 X 15014.23.40.11.50.52.662.74.497.19
3 X 18515.93.40.11.60.52.666.65.128.49
3 X 24018.33.40.11.70.52.872.45.9910.42
3 X 30020.43.40.11.80.5377.56.8612.42
3 X 40023.23.40.11.90.83.285.48.9716.05
3 X 50026.43.40.120.83.493.710.6519.5


No.X Nominal Cross Section of ConductorNominal Diameter of ConductorNominal Thickness of InsulationNominal Thickness of Copper Tape ScreenNominal Thickness of Inner SheathNominal Thickness of Steel Tape ArmouringNominal Thickness of PVC SheathApprox. Overall DiameterApprox. Weight
Al ConductorCu Conductor
No. X mm2mmmmmmmmmmmmmmkg/mkg/m
3 X 2564.50.11.40.52.148.62.532.98
3 X 356.94.50.11.40.52.250.72.763.39
3 X508.24.50.11.50.52.353.93.13.95
3 X 709.74.50.11.50.52.457.43.514.74
3 X 9511.34.50.11.50.52.661.24.055.75
3 X 12012.84.50.11.60.52.664.74.566.72
3 X 15014.24.50.11.60.52.767.95.047.74
3 X 18515.94.50.11.70.52.871.95.669.04
3 X 24018.34.50.11.80.5377.76.5611
3 X 30020.44.50.11.90.83.284.18.3913.96
3 X 40023.24.50.120.83.390.59.7116.79
3 X 50026.44.50.12.10.83.598.811.4520.57


No.X Nominal Cross Section of ConductorNominal Diameter of ConductorNominal Thickness of InsulationNominal Thickness of Copper Tape ScreenNominal Thickness of Inner SheathNominal Thickness of Steel Tape ArmouringNominal Thickness of PVC SheathApprox. Overall DiameterApprox. Weight
Al ConductorCu Conductor
No. X mm2mmmmmmmmmmmmmmkg/mkg/m
3 X 25








3 X 356.95.50.11.50.52.455.63.143.77
3 X508.25.50.11.50.52.558.63.494.34
3 X 709.75.50.11.50.52.662.13.935.16
3 X 9511.35.50.11.60.52.665.74.466.16
3 X 12012.85.50.11.70.52.769.457.15
3 X 15014.25.50.11.70.52.872.65.498.19
3 X 18515.95.50.11.80.5376.96.169.53
3 X 24018.35.50.11.90.83.283.97.8712.31
3 X 30020.45.50.120.83.288.68.9614.52
3 X 40023.25.50.12.10.83.595.410.3517.43
3 X 50026.45.50.12.20.83.7103.712.4520.23


No.X Nominal Cross Section of ConductorNominal Diameter of ConductorNominal Thickness of InsulationNominal Thickness of Copper Tape ScreenNominal Thickness of Inner SheathNominal Thickness of Steel Tape ArmouringNominal Thickness of PVC SheathApprox. Overall DiameterApprox. Weight
Al ConductorCu Conductor
No. X mm2mmmmmmmmmmmmmmkg/mkg/m
3 X 25








3 X 35








3 X508.280.11.70.52.870.44.565.41
3 X 709.780.11.70.52.973.95.046.26
3 X 9511.380.11.80.5377.75.627.32
3 X 12012.880.11.90.83.282.86.999.15
3 X 15014.280.11.90.83.285.87.5610.26
3 X 18515.980.120.83.389.98.311.67
3 X 24018.380.12.10.83.595.79.3613.79
3 X 30020.480.12.20.83.6100.610.5116.07
3 X 40023.280.12.30.83.8107.211.9919.07
3 X 50026.480.12.40.84120.114.1523.85


Products
Leave a Message to Honrey

As a one-stop cable procurement service supplier of electrical wires & cables, Honrey will be at your service.

Related Medium Voltage Power Cable

Honrey Electrical Cable News

Contact Us EMAIL
sales@honreycable.com
PHONE
0371-61288078
ADDRESS
No.195, Funiu Road, Zhengzhou City, Henan Province, China